Atmos-Tech Industries
 |
 |
The Economy Table Top
Unit |
|
|
The Economy Table Top filtration unit is constructed of high-density
particle board, epoxy painted steel or stainless steel and all exposed
surfaces are covered with Formica. The adjustable voltage
regulator maintains a nominal 100 FPM air velocity. The sterile air
produced across the work area meets class 100 and ISO requirements
(Federal Standard 209B); the 99.99% HEPA filter efficiency removes all
particles 0.3 micron or larger. |
|
|
|

|
 |
Laminar Flow Table Top
Series |
|
The
high density particle board, epoxy painted steel or stainless steel
construction of the Laminar Flow Table Top unit reduces noise and
vibration. The HEPA filters incorporated into these units guarantee
99.99% efficiency in removing all particles of 0.3 micron or larger.
The sterile air produced across the work area meets the requirements
of class 100 of Federal Standard 209B, ISO and bioclean conditions.
|

 |
 |
Laminar Downflow Work
Station |
|
Also referred to as the "CAT Series", this system
features expandability, mobility, reduced floor space
requirements, vibration resistance, low maintenance and superb
workmanship, all with an excellent delivery schedule and a
reasonable cost. With four distinct models, Atmos-Tech
offers its customers a unit which is right for their specific
application. Whether it is a single pass system or a
combination of recirculating and exhausting systems, there is a
model to meet every need.
|
|
 |

 |
 |
Recirculating System |
|
The operation of a recirculating system is similar to that of a
single pass unit. With this system the air is recirculated
through a perforated work deck to a rear-mounted return air
duct. This returns the air to the blower intake where it is
forced through the HEPA filter again and returned back to the
clean zone.
Single Pass System:
Ambient air enters the pre-filter area and is forced through
a HEPA filter, affording downward laminar flow through the clean
zone. The air is then exhausted out the front of the
unit. If necessary, the work deck can be perforated to
allow air to pass directly through the unit and then out below
the work deck.
|
|
 |

 |
 |
Clean
Hood Fume Exhaust |
|
The design of the Clean Fume Hood-Exhaust includes a perforated work
deck. Ambient air enters the system at the top, pressurizes
the blower plenum and then the clean air is forced through the HEPA
filter with 99.99% effectiveness. The air travels in a laminar
flow down through the perforated work surface into the plenum area
below and exhausts through the rear mounted exhaust duct to the
outside of the central exhaust system as determined by the design.
|
|
|
|
|
|
 We
are proud to also represent Leathwerwood Plastics, manufacturers and
distributors of a complete line of equipment for semicondutor or
circuit board production, as well as other metal finishing processes.SEMI
|
Laminar
Flow Work Stations
|
|
| Laminar
Flow Benches Feature: |
 |
Polypropylene
construction
|
 |
Laminar
flow HEPA fan/filter module
|
 |
Lighted
work area
|
|
 |
Adjustable
rear exhaust slots, and tank perimeter exhaust
|
 |
Modular
workdeck to allow for tanks or other modifications
|
|
|
FM4910-Approved
CPVC materials are available for bench construction
|
|
Portable
Laminar Flow Workstation,
Model
9046
|
Laminar
Flow C-Frame Stand,
Model
9726
|
|
Portable
Laminar Flow Enclosure,
Model
8746
|
|

|

|

|
|
Other
sizes and configurations may be built to order
|
|
Laminar
Flow Enclosures Feature:
|
|
Model
9046:
Stainless
steel work surface
Internal
work area is 48" wide x 30" deep x 32"
high
Polypropylene
upper unit construction
Stainless
steel frame and large locking casters
One
laminar flow HEPA fan/filter module, 24"x36"
Static-dissipative
PVC walls with swinging sash, or option solid
polypropylene walls
ULPA
fan/filter models are also available
|
|
Model
9726:
Stainless
steel work surface
Internal
work area is 48" wide x 30" deep x 32"
high
Polypropylene
upper unit construction
Powder
coated steel frame with leveling legs
One
laminar flow HEPA fan/filter module, 24"x36"
Open
C-frame construction
ULPA
fan/filter models are also available
|
Model
8746:
Designed
for use in Class 100 (or cleaner) clean rooms
Internal
work area is 96" wide x 36" deep x 74"
high
Polypropylene
upper unit construction
Powder
coated steel frame and large casters
Two
laminar flow HEPA fan/filter modules, each 24" x
36"
Static-dissipative
vinyl soft walls, or optional solid polypropylene walls
ULPA